STRAND® acoustic roof ventilator
OVERVIEW
With Arcadia’s Strand® HC noise control solution it is not necessary to lose the benefits of natural ventilation due to noise pollution requirements. Strand® HC has been designed as an option to incorporate a high performing noise absorption material. As air is exhausted through the ventilator the acoustic lining minimises noise transmission from the building. This also limits the transmission of noise entering the building. The acoustic lining has high flame retardant and chemical resistant properties. All Ventilators are designed to incorporate operable damper systems enabling open/close function to manage natural ventilation, noise control, heat, and integration with fire and smoke management systems.
Facilities for heavy manufacturing, power generation, water pumping and desalination have taken advantage of this for many years by incorporating the Strand® HC with added acoustic attenuation. The MKII Roof ventilator is used in both ridge and slope applications for managing low to medium heat loads. This product is CSIRO Tested and exceeds the requirements of AS2428.
Strand® MkII
|
THROAT |
150mm – 900mm |
LENGTH |
1.2m – any requirments |
PRODUCT |
Preassembled, knock down form |
FINISHES |
Aluminium, Zincalume, Colourcoated, Stainless, Galvanised |
CONTROL OPTIONS |
Internal Dampers – Electric, Pnuematic |
TESTING |
Laboratory Tested to AS2428,1,2,3,4,5 |
PERFORMANCE |
Certified CD of 0.57 + |
|
Strand® HC
|
THROAT |
600mm – 4500mm |
LENGTH |
1.2m – any requirments |
PRODUCT |
Preassembled, knock down form |
FINISHES |
Aluminium, Zincalume, Colourcoated, Stainless, Galvanised |
CONTROL OPTIONS |
Internal Dampers – Electric, Pnuematic |
TESTING |
Laboratory Tested to AS2428,1,2,3,4,5 |
PERFORMANCE |
Certified CD of 0.76 + |
|
Strand® Acoustic
|
Strand® Roof Ventilators can be internally lined with Acoustic absorption foam which ensures reduction of noise emissions from the Ventilator. Facilities for heavy manufacturing, power generation, water pumping and desalination have taken advantage of this for many years by incorporating the Strand® HC with added acoustic attenuation. The MKII Roof ventilator is used in both ridge and slope applications for managing low to medium heat loads. This product is CSIRO Tested and exceeds the requirements of AS2428.
|
Strand® Acoustic
|
Strand® Roof Ventilators can be internally lined with Acoustic absorption foam which ensures reduction of noise emissions from the Ventilator. Arcadia Strand® acoustic ventilators enable building designers to take advantage of natural ventilation for the extraction of heat, fumes and smoke whilst dealing with noise emmisions via the acoutic treated ventilator. The Strand® HC Roof ventilator is used in both ridge and slope applications for managing extreme heat loads. This product is CSIRO Tested and exceeds the requirements of AS2428.
|